Table 1 Dose-volume parameters (a) and conformity indices (b) for the optimized planning target volume (PTV optim )

From: Whole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT?

 

D2[Gy]

D98[Gy]

Dose homogeneity [%]

 

Prone

Supine

Prone

Supine

Prone

Supine

 

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

Mean

SEM

SD

(a)

W-TF

52.3

0.1

0.6

53.1

0.2

0.9

47.6

<0.1

0.1

47.9

<0.1

0.4

90.6

0.3

1.1

89.7

0.5

2.1

TF-IMRT

52.0

0.2

0.8

52.6

0.2

0.8

47.8

<0.1

0.3

47.9

0.1

0.5

91.8

0.4

1.7

90.7

0.5

2.3

MB-IMRT

51.6

0.2

0.7

52.6

0.1

0.6

47.9

<0.1

0.2

47.7

<0.1

0.2

92.5

0.3

1.4

90.3

0.3

1.2

 

Jaccard index [%]

Dose-coverage index [%]

Mismatch index [%]

 

Prone

Supine

Prone

Supine

Prone

Supine

 

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

mean

SEM

SD

(b)

W-TF

74.9

2.0

8.5

52.9

3.6

15.2

97.2

0.2

1.0

96.2

0.6

2.4

23.9

2.0

8.6

46.8

3.6

15.4

TF-IMRT

74.8

1.5

6.2

64.6

2.1

8.9

97.7

0.2

0.8

96.6

0.3

1.2

24.4

1.5

6.4

34.7

2.1

9.1

MB-IMRT

77.1

1.4

5.9

70.5

1.6

6.7

97.8

0.1

0.6

96.5

0.2

1.0

22.1

1.4

6.0

28.5

1.6

6.8

  1. Abbreviations: SEM Standard error of the mean, SD Standard deviation, W-TF Wedged tangential fields, TF-IMRT Tangential field intensity-modulated radiation therapy, MB-IMRT Multi-beam intensity-modulated radiation therapy.