Skip to main content

Table 4 Inter-observer variability for IG-4D and IG-ITV separately in left-right direction (LR), superior-inferior direction (SI) and anterior-posterior direction (AP)

From: Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

  

Variability as standard deviation between observers

Variability as maximum range between observers

  

LR[mm]

SI[mm]

AP[mm]

LR[mm]

SI[mm]

AP[mm]

IG-4D

All observers

0.3

0.6

0.3

0.9

1.8

0.7

ROs

0.3

0.5

0.2

0.6

0.9

0.4

RTTS

0.3

0.4

0.3

0.5

0.8

0.6

IG-ITV

All observers

0.8

1.5

1.0

2.2

3.8

2.8

ROs

0.8

1.6

0.9

1.6

3.1

1.7

RTTS

0.6

1.2

0.9

1.1

2.2

1.8

  1. Inter-observer variability is shown for all six observers and separately for the three ROs and three RTTs.