Figure 1 | Radiation Oncology

Figure 1

From: Is there an advantage to delivering breast boost in the lateral decubitus position?

Figure 1

Representative beam arrangement, beam energy and coverage in lateral decubitus versus supine positioning in two different patients. (A) 12 MeV beam energy resulted in an adequate coverage in the lateral decubitus position in patient A. (B) 20 MeV beam energy was needed to reach an adequate coverage when patient A in supine position. 90% isodose line-14.4 Gy -was highlighted to review the coverage. (C) 16 MeV beam energy resulted in an adequate coverage in the lateral decubitus position in patient B. (D) 20 MeV beam energy did not result in an adequate coverage of the surgical bed when patient B in supine position. 90% isodose line-14.4 Gy -was highlighted to review the coverage.