Skip to main content

Table 2 Planning objectives/constraint set

From: Sparing the contralateral submandibular gland without compromising PTV coverage by using volumetric modulated arc therapy

Target Volume min dose (Gy) max dose (Gy) priority
PTV elective (1.65 Gy/fr) 57 58.5 120-130
PTV elective (1.55 Gy/fr) 53.5 55 120-130
PTV boost 69 71 120-130
spinal cord   36 125
standard ring DVH 90-110
parotids DVH, adapt during first iterations 80
CLSM DVH, adapt during first iterations 80
Shoulders   20 75