Skip to main content

Table 1 The systematic and random setup errors and setup margins in the lateral (LR), superior-inferior (SI) and anterior-posterior (AP) directions with different correction action levels (CALs)(based on the 75 pre-treatment CBCT data sets).

From: Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation

CAL

LR

SI

AP

 

Systematic setup error (mm)

Random setup error (mm)

Margin (mm)

Systematic setup error (mm)

Random setup error (mm)

Margin (mm)

Systematic setup error (mm)

Random setup error (mm)

Margin (mm)

3 mmCAL

0.9

1.2

3.1

0.9

1.4

3.2

0.7

1.1

2.5

4 mmCAL

1.1

1.5

3.8

1.2

1.7

4.2

0.9

1.2

3.1

5 mmCAL

1.3

1.6

4.4

1.7

1.9

5.6

1.5

1.6

4.9

6 mmCAL

1.6

1.8

5.3

2.1

1.9

6.6

1.9

1.6

5.9

nocorrection

2.1

1.8

6.5

3.1

2.3

9.4

2.3

2.0

7.2