Skip to main content

Table 2 Protocols for stage IA and IB NSCLC

From: Clinical outcomes of stereotactic body radiotherapy for stage I non-small cell lung cancer using different doses depending on tumor size

First author (Ref)

Prescribed dose

(Gy/fraction)

Reference point

Isocenter dose (Gy/fraction)

Calculation algorithm/inhomogeneity correction

Nagata (2)

48/4

isocenter

48/4

PBC

/yes

Onimaru (3)

40 or 48/4

isocenter

40 or 48/4

Clarkson or superposition

/yes

Koto (4)

45/3 or 60/8

isocenter

45/3 or 60/8

BPL

/yes

Baumann (5)

45/3

67% at PTV periphery

67.2/3

PBC

/yes

Takeda (6)

50/5

100% at PTV periphery

62.5/5

MG superposition

/yes

Fakris (7)

60/3*

66/3**

80% at least 95% of PTV

at least 79.4/3*

at least 86.8/3**

unspecified

/no

Our study

48/4*

52/4**

isocenter

48/4*

52/4**

PBC

/yes

  1. * = for stage IA, ** = for stage IB.
  2. Abbreviations: PBC = Pencil beam convolution; BPL = Batho power law; MG = Multigrid.