Skip to main content

Table 4 Dose Volume Metrics of the PTV1

From: Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer

 

3DCRT

Targeting

Avoidance

ANOVA

3DCRT – Targeting

3DCRT – Avoidance

Targeting – Avoidance

D99%

65.18 ± 1.68

65.60 ± 0.59

66.91 ± 0.59

P < 0.001

P < 0.001

P < 0.001

P = 0.001

D95%

68.03 ± 0.97

68.04 ± 0.16

68.06 ± 0.08

P < 0.001

P < 0.001

P < 0.001

NS

D5%

72.15 ± 0.46

71.69 ± 0.35

70.22 ± 1.10

P < 0.001

P < 0.001

P = 0.004

P = 0.005

D1%

72.30 ± 0.47

72.35 ± 0.49

70.84 ± 1.09

P < 0.001

P < 0.001

P < 0.001

P = 0.002

D99%-D1%

-7.12 ± 1.63

-6.75 ± 0.95

-3.93 ± 1.63

P < 0.001

NS

P = 0.002

P = 0.001

D95%-D5%

-4.12 ± 0.92

-3.65 ± 0.34

-2.16 ± 1.09

P < 0.001

NS

P < 0.001

P = 0.002

  1. 3DCRT = Three Dimensional Conformal Radiation Therapy; Targeting = Conformal Pelvic Vessel Targeting; Avoidance = Conformal Normal Tissue Avoidance; ANOVA = Repeated Measures Analysis of Variance